+44 (0) 2380 741700

Silo Load Cell SI-1.0

The Silo Mount Load Cell from DLM offers a complete vessel weighing solution incorporating lift off prevention and vessel expansion without compromising accuracy.

It features a fully welded sensor and is manufactured from high tensile stainless steel type 17-4-PH for endurance durability and corrosion resistance.

The sensor becomes an integral part of your assembly and eliminates the need for vessel restraints or check rods.

Intrinsically safe certification is also available and eliminates the need for vessel restraints or check rods.

We can also offer customised designs suited to your exact specification as well as a selection of optional accessories including stainless steel brackets and a range of instrumentation.

Silo Systems
Silo Load Cells can be supplied with full load monitoring systems including panel meter/HMI displays, ticket printers, digital and analogue retransmissions. Systems can be designed to meet clients exacting specifications, please contact us to discuss your full requirements.

Vessel Weighing Assembly

  • Low cost installation
  • Five sizes
  • Stainless Steel Load Cell
  • Sealed to IP68
  • High accuracy
  • High resistance to off axis loads
  • Allows vessel expansion/contraction
  • Integral lift off prevention

Finishes

Available in following finishes for the mounting bracket:

  • Standard – Zinc Phosphate & Black E-Coat with powder coated Yellow.
  • Any Ral colour to be powder coated over the standard finish in replace of Yellow.

Dimensional Data

Type Part Number Capacity Dimensions Min Expansion
A B C D E ØF No. F G
Size 1 0001 – 1087 1 – 5t 105 150 94 124 88 13 8 12.7 3mm
Size 2 0001 – 1088 2 – 20t 140 200 125 165 117 18 8 18 4mm
Size 3 0001 – 1089 10 – 50t 175 280 175 230 162 22 8 25 6mm
Size 4 0001 – 1090 75t 240 300 190 250 184 26 12 25 6mm
Size 5 0001 – 1091 100t 250 320 230 300 210 26 12 30 8mm

Specification

Capacities0.5t, 1t, 2t, 5t, 7,5t, 10t, 20t, 30t, 50t, 75t, 100t
Full Load Output2.0 mV/V
Zero Load Output10V (15V)
Accuracy (combined error)<0.05%
Repeatability<0.01%
Input Resistance750Ω (+/-20)
Output Resistance700Ω (+/-2)
Compensated Temp. Range-10 to +50°C
Operating Temp. Range-25 to +70°C
Temp. Coefficient on Zero<0.005% Capacity/°C
Temp Coefficient of Span<0.003 Capacity/°C
Safe Overload150% of SWL
Insulation>500MΩ@100Vdc
Environmental ProtectionIP68
Email DLMContact Us