+44 (0) 2380 741700

Standard Shackle Load Cell SS-2.0

The DLM Standard Shackle Load Cell is a high strength marine grade cable connected Load Cell. Manufactured from industry leading Crosby and GN Shackles along with a stainless steel Load Pin.

The DLM Standard Shackle Load Cell offers a robust and “easy to use” tension monitoring solution for various applications. It is supplied with 10m of tough PUR signal cable as standard and can be combined with either a TW-2.0-S Hand Held Display or custom display to show the Load.

Features:

  • Rugged design
  • Stainless steel construction
  • Low headroom when rigged
  • High IP rating
  • Multiple output optins (mV/V, 4-20mA, 0-10V, RS485 ASCII, RS485 MODBUS)
  • Supplied with load centering bibbin

Applications

  • Umbilical Load Monitoring
  • Under hook crane weighing
  • Cable tension monitoring
  • Heavy lift
  • Bollard Pull and Certification

Dimensional Data

Load Capacity
(tonnes)
Part Number Shackles Dimensions
(mm)
Proof Load
(tonnes)
Accuracy
(% FRO)
Resolution
(kg)
A B C D E F G H I
12 0001 – 1059 Crosby G2130 146 76 31.8 35 107 51.5 235 100 60 18 <±1 5
25 0001 – 1060 Crosby G2130 225 106 44.5 50 162 73 100 86 37.5 37.5 <±1 10
55 0001 – 1061 Crosby G2130 327 145 66.5 70 246 105 385 100 114 82.5 <±1 50
85 0001 – 1062 GN H9 365 165 76 82 308 127 444 110 130 127.5 ±1 100
120 0001 – 1063 GN H10 416 200 89 95 347 150 493 110 150 180 ±1 100
200 0001 – 1064 GN H10 530 260 120 125 450 180 600 140 235 300 ±1 100
300 0001 – 1065 GN H10 565 305 130 150 534 200 640 150 287 350 ±1 100
400 0001 – 1192 GN H10 655 350 165 175 600 230 720 185 345 600 ±1 100
500 0001 – 1193 GN H10 710 370 180 185 610 255 780 200 375 750 ±1 100

Specification

Pin material17-4PH H1150+1150 stainless steel
Bridge resistance350Ω
Operating temperature-20°C to +60°C
DisplayTW-2.0-S Cable hand held display
Signal Cable10m of PUR screened signal cable as standard
ProtectionIP66 with Mil Spec Connector / IP67 with cable gland
CalibrationSupplied with calibration and proof load certificates to BS EN 10002/2 1992
PackagingWooden stowage case